Poseidon model 3262 - max 6 IT bus sensors (Temperature & Humidity), WEB, XML, SNMP, Email
Recommended evaluation set for Poseidon model 3262, power adapter, CD and one temperature sensor included
Poseidon model 3468 industrial - DIN rail housing, 4 DI , 2 relay DO, max 4 1W bus (1-Wire) sensors, WEB, XML, SNMP, Email, Modbus/TCP
Poseidon model 3265 - max 5 IT bus (1-Wire) sensors, WEB, XML, SNMP, Email, Modbus/TCP, GSM modem support
Evaluation set for 3265 model, G10 GSM modem. Package with two power adaptors, Poseidon 3265, GSM modem, connecting cables, one temperature sensor and CD.
Poseidon model 3266 - max 3 IT bus (1-Wire) sensors, 4 dry contact inputs, WEB, XML, SNMP, Email, Modbus/TCP
Poseidon model 3266 evaluation set, power adapter, CD, door contact, one temperature probe included
Poseidon model 3266 evaluation set, power adapter, door contact, CD, temperature and humidity probes included
Poseidon model 3268 - 2 internal relay outputs, max 4 IT bus (1-Wire) sensors, 4 dry contact inputs, WEB, XML, SNMP, Email, Modbus/TCP
Recommended Poseidon model 3268 evaluation set, power adapter, door contact, temperature probe
Poseidon 3268 with -48V power - 4 digital dry contact inputs, 2 internal relay outputs, max 4 1W bus (1-Wire) sensors, WEB, XML, SNMP, Email, Modbus/TCP
Poseidon model 1250 - max 31 Industrial bus (RS-485) & max 10 IT bus (1-Wire) sensors, 3 dry contact inputs and 2 outputs, WEB, XML, SNMP, Email, Modbus/TCP
Recommended start set Poseidon model 1250, power adapter and one temperature sensor
Extended start set Poseidon model 1250, power adapter and one temperature/ humidity sensor
Poseidon model 2251 - Flash logger with GSM modem support, max 31 Industrial bus (RS-485) & max 10 IT bus (1-Wire) sensors, 3 dry contact DI, 2 DO outputs viar RS-232, WEB, XML, Email, Modbus/TCP
Recommended evaluation set Poseidon model 2251 power adapter, CD and one temperature sensor included
Recommended evaluation set Poseidon model 2251 with GSM modem included, power adapter, CD and one temperature sensor included
Simple temperature monitoring starter kit. Contains one temperature probe, Wall plug power adaptor, Poseidon model 3262, CD and special Starting guide. Support Email, SNMP, XML
Simple GSM temperature monitoring starter kit. Contains one temperature and one temperature/humidity probes, Wall plug power adaptors, Poseidon model 3265, GSM modem, CD and special Starting guide. Support Email, SNMP, SMS, XML
One Outdoor temperature sensor with logger, GSM interface, Email, GPRS and SMS support
Damocles module MINI - 4 Digital inputs, 2 relay outputs. Interfaces: WEB, XML. SNMP, Modbus/TCP. Email and SNMP Alarming
Damocles module MINI recommended starting set. Damocles MINI, wall plug power adaptor, seriál laplink and manual included.
Damocles MINI with -48V power - 4 Digital inputs, 2 relay outputs. Interfaces: WEB, XML. SNMP, Modbus/TCP. Email and SNMP Alarming
Damocles model 2404 - DIN Rail enabled metal box, 24 Digital inputs, 4 relay outputs. Interfaces: WEB, XML. SNMP, Modbus/TCP. Email and SNMP Alarming
Damocles 2404 recommended start set. Damocles 2404, Wall plug power adaptor, serial laplink and manual included.
Damocles 2404 extended start set. Damocles 2404, Temperature sensor Temp-232, power adaptor, serial laplink and manual included.
Damocles model 2404i - Industrial DIN Rail plastic box, 24 Digital inputs, 4 relay outputs. Interfaces: WEB, XML. SNMP, Modbus/TCP. Email and SNMP Alarming
Damocles 2404i recommended start set. Damocles 2404i, Wall plug power adaptor, serial laplink and manual included.
Starting set of the Damocles 0808e based on Charon 2 DB board. Will be replaced by special board Damocles 0808e set 600285
Damocles model 0808 embedded - 8 Digital TTL inputs, 8 digital TTL outputs. Interfaces: WEB, XML. SNMP, Modbus/TCP. Email and SNMP Alarming
Standalone IP Watchdog Lite in SOHO plastic housing. Two refresh methods supported - PING in and PING out.
Complete package of IP Watchdog Lite, power source, 2 dual terminal boards, CD with software and manual.
IP WatchDog Lite with terminal board to switching power supply reduction over power connector (600 221).
IP WatchDog Lite designed to reset servers
IP WatchDog Lite with two bipolar relays for DIN molding with LED signalization
Starting set of Industrial IP Watchdog unit, 2 channels with relay, PING in, Ping OUT, WEB in, WEB out, RS-232 function detection. WARNING: Relays output configuration required by ordering number
2-pin terminal I/O plug to IP WatchDog Lite, Damocles MINI and Poseidon 326x devices
IP WatchDog Lite FW update to support 4 refresh methods. Original PING in, PING out and additionally HTML page request (incomming) and HTML page with defined text string validation (outgoing).
PortBox PL device RS-232/485 over Ethernet. TCP/IP Client, Server, UDP, remote serial port modes, 9. bit support. Unit only.
Recommended starting set: PortBox PL, EU Power adaptor, DB9 LapLink cable 2m, Manual, CD
The I/O Controller in plastic housing with 20-pin terminal block. The connectors "20 pin connector" [600 034] included.
Recommended start set for I/O Controller PL, device unit, EU power adaptor, Test board, LapLink Cable and CD + manual included
Special I/O Controller version with 12 Inputs, 4 Outputs - terminal block connector
Two 10 pin green connectors for connecting peripherals to standard I/O Controller. One set already delivered with the I/O Controller unit
A test board for easy setup and debugging of your applications for the I/O Controller. It's connected to 20 pin connector in the delivery.
Remote serial port and 2 relays controlled over TCP/IP. Relay output can be used for 230V / 16A AC
Evaluation set to start work with IP Relay. Power Adaptor, CD, serial cable and IP relay HWg-ER02a unit
The I/O Controller in DIN rail housing with 8DI, 4DO (relays), RS-232/485. Industrial version up to 30V.
Optical Isolator for RS-232 serial line up to 19 200 Bd, Ext. power required
Evaluation set to start work with I/O Controller ER84a. Power Adaptor, CD, serial cable and I/O Controller ER84a unit
PortStore2 PL unit without any accessory. TCP/IP terminal sever with 2048 kB FLASH memory for incoming serial data. TCP Client connection supported in case of full buffer.
PortStore2 PL recommended starting set: PortStore unit, EU power adaptor, Manual, CD serial cable
PortStore4 unit without accessories. Serial port & IP 32 Mb buffer for PBX & iPBX. Second serial port for remote serial port only.
PortStore4 SET is the PS4 unit with accessories (Power Adaptor, 2 serial cables, CD..)
PortStore2 PL plain unit without any accessories. Version with DTR control. TCP/IP terminal sever with 2048 kB FLASH memory for incoming serial data. TCP Client connection supported in case of full buffer. Controlable DTR pin
PortStore2 PL recommended starting set: PortStore 2 PL (DTR version) unit, EU power adaptor, Manual, CD serial cable
1-Wire Temperature sensor on a 1 meter long cable with RJ12 connector, encased in black covering.
1-Wire Temperature sensor on a 3 meter long cable with RJ12 connector, encased in black covering.
1-Wire Temperature sensor on a 10 meter long cable with RJ12 connector, encased in black covering.
RS-232 based temperature sensor, Cannon DB9M / 1.4 m, encased in black covering.
IT bus (1Wire) temperature Multi-purpose watertight (IP67) sensor probe -80 to +120°C, stainless steel 17241 with PVC cable 3m
IT bus (1Wire) temperature watertight (IP67) sensor probe for freezers, -80 to +120°C, stainless steel 17241 with flat cable 3m
Temperature sensor for IT bus (1-Wire), 2 RJ12 connectors. Sensor designed for 19" rack cabinets
Temperature & Humidity sensor for IT bus (1-Wire), 2 RJ12 connectors. Sensor designed for 19" rack cabinets
1-Wire Humidity sensor, 1 meter long cable, RJ12 connector. Sensor encased in black spaghetti insulation.
1-Wire Humidity sensor, 3 meter long cable, RJ12 connector. Sensor encased in black spaghetti insulation.
1-Wire Humidity sensor, 10 meter long cable, RJ12 connector. Sensor encased in black spaghetti insulation.
Temperature & Humidity sensor for IT bus (1-Wire), 2 RJ12 connectors. Boxed sensor designed for internal use
Temperature probe - RS-485 bus, room box2 wall mountable, RJ45 and terminal I/O screw block inside the box.
RS-485 bus room temperature sensor, a box for wall mounting with connecting terminal I/O screw block inside the housing.
Temperature & Humidity probe - RS-485 bus, room box2 wall mountable, RJ45 and terminal I/O screw block inside the box.
RS-485 bus room temperature and humidity sensor, designed for vertical wall mounting with connecting block inside the housing.
Humidity & Temperature probe (-30 to +80°C) with LCD display and RS-485 interface. Outdoor usage with IP40 for probe limitation. Compatible with Poseidon 1250 and 2251.
Humidity & Temperature probe (-30 to +105°C, 1m probe) with LCD display and RS-485 interface. Outdoor usage with IP40 for probe limitation. Compatible with Poseidon 1250 and 2251.
Barometric pressure & Humidity & Temperature probe with LCD display and RS-485 interface. Compatible with Poseidon 1250 and 2251.
Temperature sensor Pt100 up to -190°C, convertor in the IP65 protected box for wall mounting (Temp-485-Pt100 "Head" version ). Pt100 temperature sensor on 3 meters cable.
The IP65 shielding protection thermometer in box for wall mounting. Based on the RS-485 converter (Temp-485-Pt100 "Head" version ) and Pt100/A temperature sensor.
The IP65 protected box for wall mounting, contains the RS-485 converter (Temp-485-Pt100 "Head" version ) and Pt100 temperature sensor on 2 meters cable (Pt100 - PT30 type).
The IP65 protected box for wall mounting, contains the RS-485 converter (Temp-485-Pt100 "Head" version) in the same box as version Cable, Pt100 sensor not included.
Converter unit from the Pt100 temperature probe to RS-485 bus. Pt100 can be connected with 2 or 3 wires, mechanic construction is intended for mounting to a unified "B" thermometer's head.
Converter unit from the Pt100 temperature probe to RS-485 bus. Pt100 can be connected with 2 or 3 wires, mechanic package for the DIN rail.
Converter unit from two Pt100 temperature probes to RS-485 bus. Both Pt100 probes can be connected with 2 or 3 wires, mechanic package for the DIN rail.
Pt100/A temperature probe sensor in metal rod made of rustles material, connected by 4-conductor silicon covered cable.
Ch1 measures voltage (0 to 15V), Ch2 measures current (0 to 25mA), communication over RS-485
Simple contact for check when doors are open
Simple set of 3 contacts for check when doors are open
Simple contact for check when doors are open
Simple set of 3 contacts for check when doors are open
Security Door contact MK4 with 3m cable.
PIR motion detector JS-20 (External product)
Detection of external AC voltage (110 to 230V), configurable AC output(110 to 230V)
Flammable gas detector GS-133 (External product)
Flood detector LD-63HS (External product)
Optical smoke detector SD-212SP (External product)
Digital AirFlow sensor with screw adjustable trigger value, 24V DC power input
Digital AirFlow sensor ready to use with Poseidon dry contacts. Digital trigger, adjustable by screwdriver
Hub for connecting 1 to 5 sensors to IT bus (1-Wire - 5x RJ12), 10 cm connecting cable
Hub for connecting 1 or 2 sensors to IT bus (1-Wire - 2x RJ12), 3 m connecting cable
Hub for connecting 1 to 5 sensors to IT bus (1-Wire - 5x RJ11), 10 cm connecting cable
Splitter for up to 8 sensors to RS-485 bus (8+1x RJ45)
IT / Industrial bus converter, connecting max 4 IT bus (1-Wire) sensors or Dry contacts to Industrial bus (RS-485)
RS-485 converter from 4 terminal pins (A, B, +, - ) to connector RJ45
RS-485 cable 0.5m, RJ45/4 pins to connect 4 terminal pins (A, B, +, - ) to connector RJ45 (3 pairs)
RS-485 cable 0.5m, RJ45/4 pins to connect 4 terminal pins (A, B, +, - ) to connector RJ45 (2 pairs)
Converter for connecting of two relays to 12V Poseidon 1250 over RS-232
External 8 relays DIN rail block, 1,,12V input, Relay contact up to 230V / 10A
Serial port spitter to connect Poseidon RC Cable (2 relay outputs) and GSM modem to one Poseidon 2251 unit
Europe plug power adaptor 12V / 0.5A
USA plug power adaptor 12V / 0.5A
UK plug power adaptor 12V / 0.5A
The power adaptor with IEC-320 C14 power plug input
12V / 1.3Ah backup power supply 12V DC, 15V AC input, EU 15V AC power adaptor included
24V DC power adaptor for AirFlow 600304, EU power connector
1 meter long cable with power jack and 2 wires on other side
G10 GSM modem to RS-232 seriál port. Antenne and EU PWR adaptor included.
Extending communication RS-232 cable, 2m long
Communication RS-232 cable LapLink (5 wires declared).
DIN Relay - 2 switch contacts 10 A
DIN Relay - 1 switch contact 10 A
Two sideways "L" plates for mounting the box on the wall. Smaller box A type (Poseidon 1250, 2251, IP Watchdog industrial).
DIN Rail plastic holder, can be placed to most of our product housings. Installation to device have to be consulted!
Wall mounting plate for the C type plastic box (I/O Controller PL, PortStorePL)
Self-adhesive hook and loop fastener 3MT Dual LockT
Standard HW group paper box for shipping devices. Just empty box
Hand tool for Terminal IO strip "WAGO" handle. Small Screwdriver can be used as well
EDGE router ER75i is a compact Ethernet (RJ45) to GSM (GPRS/EDGE) converter. Antenna & power supply included, SIM card not included.
L profile for 19" cabinet montage (Poseidon 4xxx)
HWg demonstration case - empty version with blank plastic boards only. Samples and devices are not included in this price.
HWg DVD set for distributors. DVD with detailed products photos & DVD with all HWg matherials.
Charon 1 module for embedded TCP/IP to RS-232 gateways. Converter FW included.
Recommended starting set for the Charon 1 module: Ch1 module, Development Kit, Serial prolong cable. Not power adaptor included.
Set of components to connect Charon 1 and Charon 2 modules to Ethernet. FB2022 signal transformer, RJ45 connector, 2 capacitors for high voltage peaks
Recommended starting set for the Charon 2 module: Ch2 module, Development Board, HW STK500, 2x16 LCD display, LapLink cable. Power adaptor not included.
Charon 2 module for embedded applications. 128 kB SRAM, 128 kB code FLASH, 512 kB SPI FLASH, Atmega128. Delivered with DEMO application loaded.
CapTemp SW licence, 50 sensors, SMS support enabled via GSM modem
4 hours of technical support to SW products (CapTemp, M1, PD Trigger)
Software example of centralised portal application
PD Trigger application, licence for 25 rules
PS Eye PortStore CDR data downloader - 15 devices licence
MonitorOne Network monitoring sw, special licence, limitted for 20 IP adresses
CapTemp SW licence, 20 sensors, no SMS support
CapTemp SW licence, 20 sensors, SMS support enabled via GSM modem
|